[Prev][Next][Index][Thread]
RE: NEON- Neon and radio interference
>> Thank you dirk, for the reply.
>> What about indoor/outdoor cold cathode lighting ?
>> What are the reasons?
>>
>> dmitrij
>>
>For cold cathode I prefer, and therefore use, the strayfield transformer
>always. No exeption. By 100 mA I use 6 kV as a maximum with 21 mm
>tubing. By 150 mA I use 5 kV as a maximum with 23 mm tubing. By 200 mA I
>use 4200 volt as a maximum with 25 mm tubing.
>Best from dirk.
Does it mean that use of electronic converters is limited just to small window signs?
Again, for what reasons?
dmitrij